Other information:
Special Tool(s) /
General Equipment
Feeler Gauge
Cleaning
Clean the exhaust manifold using a suitable solvent. Use
a plastic scraping tool to clean the gasket sealing surfaces.
Inspection
NOTE:
New exhaust manifold gaskets, studs, nuts and/or
bolts must be installed when an exhaust manifold is serviced.
NOTE:
Use a Straightedge that is calibrated by the ..
Removal
NOTE:
Removal steps in this procedure may contain installation details.
Detach the clips and pivot the instrument panel LH lower trim panel downward.
Disconnect the EPB switch electrical connector.
Remove the 3 screws and the EPB switch.
Installation
To install, reverse the removal..